BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//swoogo.com//NONSGML kigkonsult.se iCalcreator 2.41.90//
CALSCALE:GREGORIAN
UID:32323436-6237-4439-b035-653336326262
BEGIN:VEVENT
UID:445584008ebf0101da41f667db929e4952aa14c5@swoogo.com
DTSTAMP:20261016T053703Z
DESCRIPTION:Transfer Function measurements offer significant advantages ove
 r traditional Band Spectrum measurements for loudspeaker calibration\, pro
 viding phase\, coherence\, and reflection arrival time data. This is cruci
 al as more loudspeakers come with built-in signal processing\, including p
 hase correction. Transfer Function measurements ensure that such processin
 g aligns with the speaker's phase correction. However\, Transfer Function 
 measurements require two channels: a reference signal and a microphone. In
  environments with limited routing options\, this can be challenging. The 
 paper introduces 'Virtual Reference\,' a method that simplifies this by us
 ing a recording of the reference signal. Virtual Reference compares the mi
 crophone signal to this recording and plays its own reference signal when 
 necessary\, allowing the analyzer to operate normally. Additionally\, Virt
 ual Reference addresses samplerate discrepancies between devices\, ensurin
 g stable phase traces and accurate measurements despite minor deviations i
 n samplerate.
DTSTART:20241024T170000Z
DTEND:20241024T173000Z
LAST-MODIFIED:20261016T053703Z
LOCATION:Session Room 1
SEQUENCE:0
STATUS:CONFIRMED
SUMMARY:Transfer Function Measurements When the Reference Signal is Known b
 ut not Accessible
TRANSP:OPAQUE
X-ALT-DESC;FMTTYPE=text/html:<p>Transfer Function measurements offer signif
 icant advantages over traditional Band Spectrum measurements for loudspeak
 er calibration\, providing phase\, coherence\, and reflection arrival time
  data. This is crucial as more loudspeakers come with built-in signal proc
 essing\, including phase correction. Transfer Function measurements ensure
  that such processing aligns with the speaker's phase correction. However\
 , Transfer Function measurements require two channels: a reference signal 
 and a microphone. In environments with limited routing options\, this can 
 be challenging. The paper introduces 'Virtual Reference\,' a method that s
 implifies this by using a recording of the reference signal. Virtual Refer
 ence compares the microphone signal to this recording and plays its own re
 ference signal when necessary\, allowing the analyzer to operate normally.
  Additionally\, Virtual Reference addresses samplerate discrepancies betwe
 en devices\, ensuring stable phase traces and accurate measurements despit
 e minor deviations in samplerate.</p>
BEGIN:VALARM
UID:38376463-3032-4537-b362-326362373862
ACTION:DISPLAY
DESCRIPTION:Transfer Function measurements offer significant advantages ove
 r traditional Band Spectrum measurements for loudspeaker calibration\, pro
 viding phase\, coherence\, and reflection arrival time data. This is cruci
 al as more loudspeakers come with built-in signal processing\, including p
 hase correction. Transfer Function measurements ensure that such processin
 g aligns with the speaker's phase correction. However\, Transfer Function 
 measurements require two channels: a reference signal and a microphone. In
  environments with limited routing options\, this can be challenging. The 
 paper introduces 'Virtual Reference\,' a method that simplifies this by us
 ing a recording of the reference signal. Virtual Reference compares the mi
 crophone signal to this recording and plays its own reference signal when 
 necessary\, allowing the analyzer to operate normally. Additionally\, Virt
 ual Reference addresses samplerate discrepancies between devices\, ensurin
 g stable phase traces and accurate measurements despite minor deviations i
 n samplerate.
TRIGGER:-PT15M
END:VALARM
END:VEVENT
END:VCALENDAR
